(0: Normal completion) (The statuses of total 8 sections (4 colors on the front and rear sides) are displayed.) 1: Y on the rear side detection abnormality (*1) 16 2: Y on the front side detection abnormality (*1) 16 3: Y on the front and rear sides detection abnormality 16 4: M on the rear side detection abnormality (*1) 16 8: M on the front side detection abnormality (*1) 16 12: M on the front and rear sides detection abnormality 16 16: C on the rear side detection abnormality (*1) 16 32: C on the front side detection abnormality (*1) 16 48: C on the front and rear sides detection abnormality 16 64: K on the rear side detection abnormality (*1) 16 85: All colors on the rear side detection abnormality 11 128: K on the front side detection abnormality (*1) 16 170: All colors on the front side detection abnormality 11 192: K on the front and rear sides detection abnormality 16 255: All colors on the front and rear sides detection abnormality 11 Other than the above: Multiple colors detection abnormality Remarks: The adjustment value is the sum of (*1), which, as in the example below, specifies the cause of the detection abnormality. When the error occurs, the value between 1 and 255 is displayed.
#Toshiba e studio 3555c fax ng 00b0 registration#
(05-4720: Displaying the cause of color registration detection error) 10 Check the displayed value. Set the value to “0” (not performed automatically).(08-4546: Position adjustment control / Mode setting) Turn the power ON while and are pressed simultaneously.7 Check if the sensor shutter is working properly. 6 Check if there is any stain on the image quality sensor (Front) and image quality sensor (Rear). Check if there is any stain or scratch on the LED head.Correct the auger and the surrounding hardware if not. 4 Check if the drum is rotated properly by turning the coupling of the cleaner unit.

"4.7.3 Transfer belt unit (TBU)" 2 Is an image created on the transfer belt? Yes 6 No 3 3 Check if there is any abnormality on the rods of the main charger cleaner.